Biobase BSC-6FA2-GL Class II A2 Biosafety Cabinet – NSF Certified 6 Feet Safety Workstation

490,000.00৳ 

Brand: Biobase | Model: BSC-6FA2-GL | Cabinet Size: 6feet | Country of Origin: China

Description

Introduction 6 Feet Class II A2 Biosafety Cabinet

The Biobase BSC-6FA2-GL 6 Feet Class II A2 Biosafety Cabinet gives large laboratories a wide, protected workspace for the operator, the sample and the environment. This NSF certified cabinet draws room air through the front grille and filters it with two HEPA filters. Moreover, the wide chamber lets two technicians work side by side. The front window stops at a 254 mm (10-inch) safe working height. A 7-inch color touch display shows airflow, filter life and alarms in real time. Biobase Scientific manufactures the cabinet in China for microbiology, cell culture and clinical testing. The cabinet pulls 824 m³/h of inflow air, so it holds a firm barrier at the front opening.

Technical Specifications biosafety cabinet price in Bangladesh

Specification Details
Brand Biobase
Model BSC-6FA2-GL
Type Class II Type A2 biosafety cabinet
Standard NSF/ANSI 49 certified
Cabinet Width 6 feet
External Dimensions (W×D×H) 1873 × 775 × 2295 mm
Safe Sash Height 254 mm (10 in)
Air Pattern Approx. 60% recirculation, 40% exhaust
Inflow Velocity 0.53 m/s (100–110 fpm)
Downflow Velocity 0.33 m/s (60–70 fpm)
Inflow Volume 824 m³/h (485 cfm)
Downflow Volume 1212 m³/h (713 cfm)
Exhaust Volume 824 m³/h (485 cfm)
HEPA Filters Two filters, 99.995% efficiency at 0.3 μm, with filter life indicator
Front Window Motorized, with interlocks to the UV lamp and blower
Display 7-inch color touch screen
Fan EC fan with automatic airflow adjustment
Lighting and Sterilization LED lamp and UV lamp with programmable timer
Work Area Material 304 stainless steel
Body Material Cold-rolled steel with antibacterial powder coating
Base Separate base with adjustable height
Front Design 10° slanted front panel
Sockets 2 waterproof sockets, total load ≤ 500 W
Alarms Abnormal airflow, filter replacement, unsafe window height, high filter pressure, power failure
Safety Functions Power-on password, scheduled start/stop timer, memory function after power failure
Noise Level ≤ 67 dB
Power Supply AC 220V ±10%, 50/60 Hz; 110V ±10%, 60 Hz
Power Consumption 500 W
Full Load Current 9 A
Heat Output 1689 BTU/hr
Manufacturer Biobase Scientific (Shandong) Co., Ltd.
Country of Origin China

 

Key Features Biobase BSC-6FA2-GL

  1. The 6-foot chamber gives two operators room to work at the same time.
  2. Two HEPA filters clean both the supply air and the exhaust air.
  3. In addition, the motorized front window glides to the safe height with a single touch.
  4. The 7-inch color touch display presents airflow and runtime data in real time.
  5. The EC fan adjusts airflow automatically, so velocity stays stable as the filters load.
  6. Alarms flag abnormal airflow, high filter pressure and unsafe window height.
  7. Two waterproof sockets power small instruments inside the chamber.
  8. Furthermore, a power-on password blocks unauthorized use.
  9. The memory function restores the previous state after a power failure.
  10. The slanted front panel reduces glare, so operators reach comfortably into the work area.

Who Uses This Biobase BSC-6FA2-GL

  1. Large hospital laboratories process high volumes of patient specimens in it.
  2. Universities and medical colleges equip shared research labs with it.
  3. Diagnostic chains run PCR and culture preparation at scale.
  4. Biotech and pharmaceutical teams run cell culture and quality control.
  5. Moreover, research institutes assign two scientists to the same cabinet for joint studies.
  6. Similarly, public health labs rely on it for outbreak sample handling.

Applications 6 feet safety workstation

  1. Technicians expand cell lines and tissue cultures in sterile downflow air Biobase BSC-6FA2-GL.
  2. Microbiologists inoculate and subculture bacterial samples.
  3. Moreover, molecular biology teams prepare PCR reactions without cross-contamination.
  4. Clinical staff handle specimens that carry moderate-risk agents.
  5. Researchers process vaccine and biologic samples during development.
  6. Finally, instructors teach aseptic technique to groups of students.
  7. However, the cabinet does not suit volatile toxic chemicals or radionuclides, so labs choose a Class II B2 cabinet for those tasks Biobase BSC-6FA2-GL.

Frequently Asked Questions / FAQ Biobase BSC-6FA2-GL

Q1. What is a 6 feet Class II A2 biosafety cabinet?
It protects the operator, the sample and the environment during work with moderate-risk biological agents. Moreover, it recirculates most of the air through HEPA filters and exhausts the rest.

Q2. What size is the Biobase BSC-6FA2-GL?
It measures 1873 × 775 × 2295 mm outside.

Q3. How much air does it move?
It pulls 824 m³/h of inflow air and delivers 1212 m³/h of downflow air.

Q4. What power supply does it need?
It runs on AC 220V ±10% at 50/60 Hz or 110V ±10% at 60 Hz, and it consumes about 500 W. Please confirm your local supply before Biobase BSC-6FA2-GL.

Q5. Can I use volatile solvents inside it?
No. Volatile toxic chemicals and radionuclides need a Class II B2 total-exhaust cabinet.

Q6. How often should I certify the cabinet?
Most labs certify it every year. They also recertify after each relocation or HEPA filter change Biobase BSC-6FA2-GL.

Q7. Does astzbd deliver across Bangladesh?
Yes, astzbd delivers to Dhaka, Chattogram and other districts. Contact the sales team for the latest price and delivery time.

Why Buy From astzbd biosafety cabinet price in Bangladesh

  1. astzbd supplies genuine Biobase laboratory equipment with proper documentation.
  2. The team quotes competitive prices for hospitals, universities and private labs.
  3. Fast delivery reaches every district of Bangladesh.
  4. Technicians guide your staff through installation and first-time operation.
  5. The after-sales team answers service and spare part requests quickly.