Hioki DT4252 Digital Multimeter — True RMS
The Hioki DT4252 Digital Multimeter is a standard-tier True RMS meter built for electricians, technicians, and industrial maintenance engineers who need higher voltage range and direct current measurement beyond what pocket-sized models offer. Available through ASTZ (Advance Science & Technology Zone), an authorized distributor of genuine Hioki instruments in Bangladesh, this model steps up from the compact DT4221 and DT4222 with a 1000V voltage range, direct current measurement up to 10A, and enhanced accuracy — making it suitable for panel testing, motor circuits, and general industrial electrical work where the 600V pocket models fall short.
Hioki DT4252 Digital Multimeter – Overview
The Hioki DT4252 Digital Multimeter belongs to Hioki’s DT4200 standard series, sitting between the compact pocket models (DT4221, DT4222) and the higher-end industrial models (DT4253, DT4256) in ASTZ’s lineup. Where the pocket models are limited to 600V and cannot measure current directly, this model adds a full step up: 1000V DC/AC voltage range, resistance up to 60MΩ, capacitance up to 10mF, diode testing, and direct current measurement up to 10A — all in a slightly larger but still portable body. It also includes MAX/MIN/Average value display and an optional USB communication function for logging readings to a PC. This DT4252 Digital Multimeter model is best understood in context — see how it compares against the rest of the lineup in the table below.
Full Specification: Hioki DT4252 Digital Multimeter
| Parameter | Specification |
|---|---|
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges, Basic accuracy: ±0.3% rdg. ±5 dgt. |
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, 40 Hz–1 kHz, Basic accuracy: ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3) |
| AUTO AC/DCV | N/A |
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7% rdg. ±5 dgt. |
| DC Current range | 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ±0.9% rdg. ±5 dgt. |
| AC Current range | 6.000 A / 10.00 A, 2 ranges, Basic accuracy: ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz–1 kHz) |
| AC Current (Clamp on probes) | N/A |
| Voltage detection (50/60 Hz) | N/A |
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9% rdg. ±5 dgt. |
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold: 0.15V–1.5V |
| Other functions | Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option) |
| Display | Main and sub displays, 4-digit LCD, max. 6000 digits, bar graph |
| Power supply | LR03 alkaline battery ×4, up to 130 hours continuous use (backlight OFF) |
| Dimensions & mass | 84 × 174 × 52 mm, 390 g (with batteries & holster) |
| Included accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 battery ×4 |
HIOKI DT4252 Price in Bangladesh
The HIOKI DT4252 price in Bangladesh is 18,500৳, discounted from 20,000৳, available at ASTZ with genuine manufacturer warranty and authentic Japan-sourced stock. This price reflects the meter’s step up in capability from the pocket-tier DT4221 and DT4222 — the added 1000V range, direct 10A current input, and MAX/MIN/Average functions justify the higher cost for technicians who work on industrial panels or need to measure current without an external clamp accessory. The HIOKI DT4252 price stays consistent across ASTZ’s stock — always confirm current pricing directly before ordering, and always buy from an authorized distributor, since counterfeit or improperly calibrated units are common in the market and can produce unreliable readings, particularly risky when working with voltages up to 1000V.
What Makes This Model Different
Compared to Hioki’s pocket-safety series, this model sits at a different tier. Unlike the DT4221 and DT4222, which are capped at 600V and cannot measure current directly, it offers a full 1000V DC and AC voltage range along with direct current measurement up to 10A — useful for testing motor circuits, industrial panels, and higher-voltage systems common in commercial and light-industrial settings. The HIOKI DT4252 multimeter shares the same resistance, capacitance, and diode test functions as the DT4222, but adds MAX/MIN/Average value display for tracking fluctuating readings over time, and an optional USB communication function for logging data to a PC. Compared to the higher-end DT4253 and DT4256, the HIOKI DT4252 multimeter does not offer clamp-on current measurement, temperature sensing, or auto AC/DCV switching — making it the right fit for technicians who need higher voltage and direct current capability without the added cost of full industrial-grade features.
Key Features: Hioki DT4252 Digital Multimeter
1. 1000V DC & AC Voltage Range
5 DC ranges and 4 AC ranges up to 1000V, with ±0.3% DC accuracy — a significant step up from the 600V pocket models, suitable for industrial panel work.
2. Direct Current Measurement up to 10A
Unlike the DT4221 and DT4222, this model measures both DC and AC current directly up to 10A without needing a separate clamp accessory.
3. Full Resistance & Capacitance Testing
Resistance up to 60MΩ across 6 ranges and capacitance up to 10mF across 5 ranges, matching the DT4222’s diagnostic capability at a higher voltage tier.
4. MAX/MIN/Average Value Display
Track the highest, lowest, and average readings over a measurement period — useful for diagnosing intermittent electrical faults or monitoring load fluctuations.
5. Optional USB Communication
Connect to a PC (with the optional communication accessory) to log and analyze measurement data over time — valuable for maintenance record-keeping.
6. Low-Pass Filter for Inverter Measurements
Filters high-frequency harmonics when measuring inverter secondary-side voltage, relevant for the growing number of solar and motor-drive installations in Bangladesh.
7. Extended Battery Life
Powered by 4×LR03 batteries offering up to 130 hours of continuous use — more than triple the runtime of the pocket-tier DT4221/DT4222 models.
DT4252 Digital Multimeter — Full Comparison Table (All Models)
| Spec | DT4221 | DT4222 | DT4252 | DT4253 | DT4256 |
|---|---|---|---|---|---|
| Price in BD | 9,100৳ | 9,800৳ | 18,500৳ | 30,000৳ | 21,000৳ |
| DC Voltage | 600V, ±0.5% | 600V, ±0.5% | 1000V, ±0.3% | 1000V, ±0.3% | 1000V, ±0.3% |
| AC Voltage | 600V, True RMS | 600V, True RMS | 1000V, True RMS | 1000V, True RMS | 1000V, True RMS |
| AUTO AC/DCV | ✕ | ✕ | ✕ | ✓ | ✓ |
| Resistance | ✕ N/A | ✓ 60MΩ | ✓ 60MΩ | ✓ 60MΩ | ✓ 60MΩ |
| Capacitance | ✕ N/A | ✓ 10mF | ✓ 10mF | ✓ 10mF | ✓ 10mF |
| Diode Test | ✕ N/A | ✓ | ✓ | ✓ | ✓ |
| Continuity Check | ✓ | ✓ | ✓ | ✓ | ✓ |
| Voltage Detection | ✓ 80–600V | ✕ | ✕ N/A | ✕ | ✓ 40–600V |
| DC/AC Current (direct) | ✕ | ✕ | ✓ up to 10A | ✓ 60μA–60mA | ✓ up to 10A |
| AC Current (clamp-on) | ✕ | ✕ | ✕ N/A | ✓ 10A–1000A | ✓ 10A–1000A |
| Temperature (K-type) | ✕ | ✕ | ✕ | ✓ -40 to 400°C | ✕ |
| MAX/MIN/Average | ✕ | ✕ | ✓ | ✓ | ✓ |
| Frequency Range | ✓ up to 9.999 kHz | ✓ up to 9.999 kHz | ✓ up to 99.99 kHz | ✓ up to 99.99 kHz | ✓ up to 99.99 kHz |
| USB Communication | ✕ | ✕ | ✓ (option) | ✓ (option) | ✓ (option) |
| Power Supply | 1×LR03, 40 hrs | 1×LR03, 40 hrs | 4×LR03, 130 hrs | 4×LR03, 130 hrs | 4×LR03, 130 hrs |
| Weight | 190 g | 190 g | 390 g | 390 g | 390 g |
| Best For | Voltage checks, live-line detection | Resistance/capacitance/diode testing | 1000V panels & direct 10A current | Full industrial diagnostics + temperature | 1000V work + clamp current + voltage detection |
Which model should you choose?
- Choose this model if you regularly work on higher-voltage systems (up to 1000V) or need to measure current directly up to 10A without an external clamp.
- Choose the DT4221 if your work is mostly voltage checking and confirming live circuits.
- Choose the DT4222 if you need general-purpose resistance, capacitance, and diode testing at 600V.
- Choose the DT4253 if you need clamp-on current up to 1000A plus temperature measurement for full industrial diagnostics.
- Choose the DT4256 if you need 1000V range, clamp-on current, and built-in voltage detection all in one meter.
Who Should Buy the Hioki DT4252 Digital Multimeter
The HIOKI DT4252 multimeter fits a specific niche among Hioki’s lineup — professionals who need more than pocket-tier voltage checking but don’t yet require full industrial clamp-current capability.
- Industrial electricians working on panels and systems rated above 600V
- Maintenance engineers who need direct current measurement up to 10A without carrying a separate clamp meter
- Facility technicians monitoring load fluctuations using MAX/MIN/Average tracking
- Solar and motor-drive technicians who benefit from the low-pass filter for inverter voltage measurement
- Quality control teams who need USB data logging for measurement records
How to Use the DT4252 Digital Multimeter
- Insert the batteries — install all 4 LR03 alkaline batteries before first use.
- Select the measurement mode — rotate the dial to DC Voltage, AC Voltage, Resistance, Capacitance, Current, Continuity, or Diode Test depending on your task.
- Connect the test leads — use the included L9207-10 test leads; for current measurement, use the dedicated current input terminal.
- For current measurement — never exceed the 10A rated input, and disconnect leads immediately after measurement to avoid fuse damage.
- Read the display — the main LCD shows the measured value; enable MAX/MIN/Average mode to track fluctuating readings over time.
- For inverter measurements — enable the low-pass filter to get accurate fundamental voltage readings free of harmonic distortion.
- Power down after use — the auto-power save feature helps, but manually switching off extends battery life further.
Maintenance & Care Tips
- Store in a dry place; avoid extreme humidity common in Bangladesh’s monsoon season
- Replace all 4 LR03 batteries together when the low-battery indicator appears, to maintain consistent accuracy
- Never exceed the rated 10A current input — doing so can blow the internal fuse or damage the meter
- Discharge capacitors fully before capacitance testing to avoid inaccurate readings
- Wipe the holster and body with a dry cloth — avoid solvents on the display window
- Periodically verify calibration accuracy, especially before critical 1000V or current measurements
Hioki DT4252 Digital Multimeter – FAQ
1. What is the HIOKI DT4252 price in Bangladesh?
The HIOKI DT4252 price in Bangladesh is 18,500৳ (reduced from 20,000৳), available at ASTZ with genuine manufacturer warranty.
2. Can this DT4252 Digital Multimeter measure current directly?
Yes. Unlike the DT4221 and DT4222, this DT4252 Digital Multimeter measures both DC and AC current directly up to 10A without needing a separate clamp accessory.
3. What voltage range does the Hioki DT4252 Digital Multimeter support?
It supports DC voltage up to 1000V (5 ranges, ±0.3% accuracy) and AC voltage up to 1000V (4 ranges, True RMS), a significant step up from the 600V pocket models.
4. What is the difference between this model and the DT4256?
The DT4256 adds AUTO AC/DCV switching, clamp-on current measurement up to 1000A, and a built-in voltage detection function. If you need those capabilities, the DT4256 is the better choice; otherwise, this model covers the same voltage, resistance, capacitance, and direct current functions at a lower price.
5. What is the difference between this model and the DT4253?
The DT4253 adds temperature measurement (K-type thermocouple), clamp-on current up to 1000A, and 4–20mA percentage conversion display, along with AUTO AC/DCV switching — making it a more complete industrial diagnostic tool. This model covers standard voltage, resistance, capacitance, and direct current needs at a significantly lower price.
6. Is the HIOKI DT4252 multimeter suitable for testing motor circuits and industrial panels?
Yes, with its 1000V voltage range and direct 10A current measurement, the HIOKI DT4252 multimeter is well suited for testing motor circuits, control panels, and industrial electrical systems that exceed the capability of pocket-tier multimeters.
7. Does the Hioki DT4252 Digital Multimeter come with a warranty in Bangladesh?
Yes, when purchased through ASTZ, the Hioki DT4252 Digital Multimeter comes with full manufacturer warranty and after-sales support.
8. Is this a genuine Japan-made product?
Yes, the Hioki DT4252 Digital Multimeter purchased through ASTZ is fully genuine, manufactured in Japan, and comes with an official warranty card.
9. How long does the battery last?
Powered by 4 LR03 alkaline batteries, it provides up to 130 hours of continuous use with the backlight off — more than three times the runtime of the DT4221/DT4222 pocket models.
10. Can this DT4252 Digital Multimeter be used with clamp-on current probes?
No, this DT4252 Digital Multimeter does not support clamp-on current probes. For clamp-on current measurement up to 1000A, consider the DT4253 or DT4256 instead.
11. What accessories are included with the Hioki DT4252 Digital Multimeter?
The package includes one L9207-10 test lead set, one holster, an instruction manual, and four LR03 alkaline batteries.
12. Is the USB communication feature included by default?
No, USB communication is an optional accessory. The meter supports it, but the communication cable/adapter must be purchased separately if PC data logging is required.
13. Where can I order the Hioki DT4252 Digital Multimeter from?
You can order directly from astzbd.com’s Digital Multimeter category, or contact via call/WhatsApp for quick delivery confirmation across Bangladesh.
Warranty & After-Sales Support
Every Hioki DT4252 Digital Multimeter purchased through ASTZ comes with genuine manufacturer warranty and dedicated after-sales support, including calibration guidance and replacement accessories such as test leads and holsters.
Related Products
- Hioki DT4221 Digital Multimeter — compact voltage-focused model with live-circuit detection
- Hioki DT4222 Digital Multimeter — general-purpose resistance, capacitance & diode testing
- Hioki DT4253 Digital Multimeter — full industrial model with clamp current & temperature
- Hioki DT4256 Digital Multimeter — 1000V range with clamp current & voltage detection
- Browse all Digital Multimeters
ADVANCE SCIENCE & TECHNOLOGY ZONE
E-mail: astzbd@gmail.com, Website: WWW.ASTZBD.COM
Cell: +88 01329100999
+88 01329100998


Reviews
There are no reviews yet.